Chapter 5 LIGHTING, VENTILATION, REFRIGERATION, AND EQUIPMENT
Controlling the manufacturing environment is important in maintaining a sanitary environment in meat and poultry operations. This chapter provides guidelines concerning lighting, ventilation, refrigeration, and equipment for meat and poultry establishments that you should consider in building or modifying an establishment.
1. Lighting
Well-distributed, good –quality artificial lighting is needed at all places where natural light is unavailable or insufficient. Lighting is critical to maintaining a sanitary environment for slaughter and processing operations. Without adequate lighting, in sanitary conditions are often difficult to see and correct. When selecting and installing lighting systems, consider the following requirements:
- Light fixtures in rooms where exposed meat or poultry is handled should ensure maximum safety, to preclude contamination of products with broken glass and prevent the collection of dirt, product, and debris on lamp surfaces, including fixture surfaces not easily cleaned or inspected.
- Lighting must be intense enough to allow both the establishment and inspection personnel to see in sanitary conditions and product contamination. The intensity of lighting is measured in foot candles. The following charts provide recommendations for minimum foot candles for artificial lighting:
GUIDELINES FOR MINIMUM LIGHTING INTENSITY IN MEAT ESTABLISHMENTS
Area | 30 ft. candles | 50 ft. candles |
---|---|---|
General lighting (in areas where animals are killed, eviscerated,and products are processed or Packaged) | X | |
Offal cooler | X | |
Carcass coolers | X | |
Freezers | X | |
Dry storage | X | |
Ante-mortem inspection | X | |
Suspect pen inspection area | X | |
Inspection stations | X | |
Establishment quality control inspection areas | X | |
Reconditioning and reinspection areas | X | |
All other areas | X |
TABLE 2.—GUIDELINES FOR MINIMUM LIGHTING INTENSITY IN POULTRY ESTABLISHMENTS
Area | 30 ft. candles | 50 ft. candles | 200 ft. candles |
---|---|---|---|
Ante-mortem inspection | X | ||
Inspection station (traditional) | X | ||
Inspection station (NELS/SIS/NTI) | X | ||
Pre and post chill inspection areas | X | ||
Reconditioning and reinspection areas | X | ||
Establishment quality control inspection areas | X | ||
All other areas | X |
Do you mind if I quote a few of your posts as long as
I provide credit and sources back to your site? My blog site is in the very same area of interest as yours and my users would truly benefit from a lot
of the information you provide here. Please let me
know if this okay with you. Cheers!
Hi, all is going sound here and ofcourse every one is sharing data,
that’s truly good, keep up writing.
Blog looks nice. I’m still trying to make a blog but it won’t be as professional as yours /: Keep on blogging 🙂 pirater un compte facebook
You need to take part in a contest for one of the highest quality blogs online.
I’m going to recommend this website!
Thank you, I’m also looking for more peoples involved to share the meat knowleadge, if you have any good idea / articles, please send to meater#outlook.com (use @ to replaced #)